Kjellberg SmartFocus 300 Short Instruction Manual page 91

Table of Contents

Advertisement

current-
relevance
display
ER 8
Gas test period
ER 9
Pilot arc
interruption
ER10
Communication
error
ER43
Coolant error
ER51
Temperature
error
ER60
Sequence error
ER70
ER71
Gas error
ER72
Pos : 18 /Steuermodul e/--------------- Seitenumbruc h --------------- @ 0\mod_1197390577023_19.doc x @ 1454 @ @ 1
LED-display
LED-signal lamp
max. time exceeded,
yellow H32
stop gas test and start
"Process error" (14)
again if required
LED-signal lamp
plasma arc
yellow H32
interruption during
"Process error" (14)
ignition (pilot source)
main arc is not formed
LED-signal lamp
CAN communication
yellow H32
between
"Process error" (14)
PGCPGV
interrupted
LED-signal lamp
coolant quantity not
yellow H31
enough
"Cumulative error"
(13) ON and green
H29 "coolant OK"
(7) OFF
LED-signal lamp
high temperature
yellow H31
"Cumulative error"
(13) ON and green
H30 "temperature
OK" (9) OFF
LED-signal lamp
Error in the cutting
yellow H32
sequence
"Process error" (14)
LED-signal lamp
gas missing
yellow H31
"Cumulative error"
gas missing at start of
(13) ON and green
power source
H28 "gas OK" (8)
OFF
gas pressure too low
Power source Smart Focus 300
cause
end or fault clearance
tumbler switch "gas test" OFF
end after ca. 1 s
Control connection
PGC - PGV
settle disturbances
settle disturbances
external release missed
check gas bottle if necessary
replace
open gas bottle
check gas, start the power
source again
75

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flowcontrol 300Pba-300

Table of Contents