Pos : 21.35 /Brenner/Allgemein/Verschl eißteile-T eil2 @ 0\mod_1200048713900_19.doc x @ 2708 @ @ 1
The life time of the nozzle mainly depends on the cutting time, the number of ignitions and the handling of
the torch (performance of hole piercing, upcoming spatter, etc.).
Be sure that the consumables are suitable for the intended cutting procedure.
The consumables shall be replaced with great care and only with the mounting aids which are part of the
delivery.
Pos : 21.36 /Warnung, Vorsic ht, Verbot, Gebot, Hi nweis /Verbots zeic hen (r ot)/Ver bot - ung eeignete Wer kzeuge für Br ennerwec hs el @ 0\mod_1199710363915_19.doc x @ 2366 @ @ 1
Under no circumstances pliers or other unsuitable tools have to be used for consumable
change, they entail inevitably the damage of the consumables, for example burr formation
and thereby malfunctions of the plasma torch.
Pos : 21.37 /Warnung, Vorsic ht, Verbot, Gebot, Hi nweis /Gebotszeic hen (blau)/Sc hutz kappe überprüfen, PerCut2000/4000 @ 13\mod_1413351612615_19.doc x @ 207997 @ @ 1
After screwing off the protective cap to replace the swirl gas cap without any further
replacement of consumables, the tightness of the nozzle cap must absolutely be checked
and, if required, tightened again before mounting the protective cap!
apply to plasma torch:
PerCut 2000
PerCut 4000
PerCut 4000 XS
Pos : 21.38 /Warnung, Vorsic ht, Verbot, Gebot, Hi nweis /Gebotszeic hen (blau)/Auf Vollständig keit der Verschl eißteile ac hten @ 0\mod_1200055848051_19.doc x @ 2782 @ @ 1
Make sure that all wearing parts are complete and correct installed!
Especially the cooling tube has to be inserted. Other wise the cooling is ineffective and the
torch gets damaged.
No other parts as mentioned before have to be changed unauthorised on the plasma
machine torch.
A further opening of the torch from the front side is not possible.
Pos : 21.39 /Steuer module--------------- Seitenumbr uch --------------- @ 0\mod_1197390577023_19.doc x @ 1454 @ @ 1
Plasma machine torch PerCut 2000/2000A / PerCut 4000/4000A
Control with flat meter feeler
Reset only with unused cathode
.16.004.810.8