Kjellberg SmartFocus 300 Short Instruction Manual page 16

Table of Contents

Advertisement

Short instruction manual Smart Focus 300 with FC-300
current-
relevance
display
ER 8
Gas test period
ER 9
Pilot arc
interruption
ER10
Communication
error
ER43
Coolant error
ER51
Temperature
error
ER60
Sequence error
ER70
ER71
Gas error
ER72
Pos : 3.51 /Steuermodul e/--------------- Seitenumbruc h --------------- @ 0\mod_1197390577023_19.doc x @ 1454 @ @ 1
Pos : 3.52 /Kurz betriebsanlei tung/Kj ellberg_Adresse @ 1\mod_1221824758746_19.doc x @ 5326 @ @ 1
Pos : 4 /Ü berschriften/Sicherheits hinweis e_Produktname @ 1\mod_1222148646980_19.doc x @ 5440 @ @ 1
- Safety
Pos : 5 /Ü berschriften/Versc hl eißteil wec hsel _Pr oduktname @ 1\mod_1222148651251_19.doc x @ 5445 @ @ 1
- Consumabl e c hang e of the plas ma torc h
Pos : 6 /Ü berschriften/Schneiddatenhandbuc h_Produktname @ 1\mod_1222088018302_19.doc x @ 5421 @ @ 1
- Cutti ng c harts
=== Ende der Liste für T extmar ke Inhalt ===
16
LED-display
LED-signal lamp
max. time exceeded,
yellow H32
stop gas test and start
"Process error" (14)
again if required
LED-signal lamp
plasma arc
yellow H32
interruption during
"Process error" (14)
ignition (pilot source)
main arc is not formed
LED-signal lamp
CAN communication
yellow H32
between
"Process error" (14)
PGCPGV
interrupted
LED-signal lamp
coolant quantity not
yellow H31
enough
"Cumulative error"
(13) ON and green
H29 "coolant OK"
(7) OFF
LED-signal lamp
high temperature
yellow H31
"Cumulative error"
(13) ON and green
H30 "temperature
OK" (9) OFF
LED-signal lamp
Error in the cutting
yellow H32
sequence
"Process error" (14)
LED-signal lamp
gas missing
yellow H31
"Cumulative error"
gas missing at start of
(13) ON and green
power source
H28 "gas OK" (8)
OFF
gas pressure too low
Kjellberg Finsterwalde Plasma und Maschinen GmbH
Germany • D - 03238 Finsterwalde • Oscar-Kjellberg-Str. 20
phone: +49 3531 500-0 • Fax: +49 3531 500-227
cause
e-mail: plasma@kjellberg.de
Internet: www.kjellberg.de
end or fault clearance
tumbler switch "gas test" OFF
end after ca. 1 s
Control connection
PGC - PGV
settle disturbances
settle disturbances
external release missed
check gas bottle if necessary
replace
open gas bottle
check gas, start the power
source again