Plasma gas control unit FlowControl-300
4
reference value corner
current for long
protocol
5
device
6
device is ...
Pos : 19.45 /Gas kons olen/FlowC ontrol/Fl owc ontrol-300/Betri eb. Konfigur ations daten-Sc haltmöglichkei ten @ 13\mod_1418117025555_19.doc x @ 211317 @ @ 1
Switching possibilities
execution
cursor to next value
change value
For operation screen "data survey"
For operation screen "support"
Fig. 28: Switching possibilities for operation screen "configuration data"
Pos : 19.46 /Steuer module--------------- Seitenumbr uch --------------- @ 0\mod_1197390577023_19.doc x @ 1454 @ @ 1
90
At signal „corner" the cutting current will be set down to the cutting current-
refernce value(1 = 1 % of the cutting current-refernce value)
global adjustable at the range 60 – 100 %
Device number
If several PGCs are operated with one Bus RS485 a distinction is possible by
the device number of the equipment. Possible settings are devices 1 - 4 .
Default setting: device 1.
Master
(for manual mode of PGC)
The PGC sends the value of the cutting current stored in the internal
database to the power source. A change of that value has to be carried out at
the PGC always.
For the data set selection of CNC via interface X6 (see section 2 of this table)
is the PGC always master.
Slave
(for CNC or manual mode of PGC)
The PGC receives instruction of a superordinated control (CNC).
Default setting: Slave
action
FIELD up / down
FIELD right / left
hand wheel
PAGE up
PAGE down