Power source Smart Focus 300
Pos : 17.64 /Ü bersc hriften/1.1/Bedi en- und Anz eigeel emente @ 0\mod_1197632890017_19.doc x @ 1812 @ 2 @ 1
6.8 Operating and display elements
Pos : 17.65 /Str omquellen/Smartfoc us/Bedi en- und Anzeigeel emente @ 13\mod_1412924542218_19.doc x @ 207716 @ @ 1
Fig. 8: Control and display elements
Pos : 17.66 /Str omquellen/Smartfoc us/Besc hr., Bedi en- und Anzeigeelemente @ 13\mod_1411973868866_19.doc x @ 205540 @ @ 1
1.
Red emergency stop device S3 "Emergency stop", (reset button)
• activated:
• unlocked:
2.
Key switch S1 "Mains ON"
• Position 0:
• Position PGC:
• Position I:
3.
Green illuminated button S2 "PA ON"
• Activation:
• signal lamp H1
ON:
4.
Selector switch S7 "Technology"
Adjustment :
• Position CNC:
• Position 1:
• Position 2:
• Position 3:
54
Plasma cutting unit OFF
Plasma cutting unit can be switched ON
Voltage for control transformer and fan of controling is OFF
Voltage for control transformer, fan of controling and PGC is ON
Voltage for control transformer, fan of controling and PGC is ON,
unit can be switched ON by S2
power ON for main transformer, cooling unit, fan and control system
power source ON
see cutting charts
- CNC- controller (all areas)
- range 1
- range 2 (starting gas)
- range 3 (starting gas and flying cutting of steel)