Kjellberg SmartFocus 300 Short Instruction Manual page 9

Table of Contents

Advertisement

Pos : 3.37 /Stromquellen/Smartfocus /Rei henfolge der Bedienung @ 13\mod_1411632089106_19.doc x @ 205208 @ @ 1
Operation sequences
Check before starting the gas supply,corresponding to the point "connection of the gas supply" of gas
console.
1.
Red emergency stop
device S3
"emergency stop" (1)
Key switch S1
2.
"Mains ON" (2)
3.
Illuminated button
green S2 „PA ON" (3)
Selector switch S7
4.
"technology" (4)
5.
Operation gas
console
6.
potentiometer P5
"cutting current" (12)
Short instruction manual Smart Focus 300 with FC-300
Unlock the button by turning it in one direction.
Turn the key switch to the position „I".
switch to "PGC" when change consumables.
• Mains voltage is applied to the control transformer.
• Display of consumables at operation screen "data set parameter" of the PGC
(only for FlowControl).
Activate the plasma unit with the illuminated push button.
Main transformer, fan, pump and control are switched on.
Inspection:
• The display screens appear for a short moment after starting the unit
following messages:
at the voltage display (17):
U-1
= device-no.
= device typ
SF
0
= voltage actual value
at the current display (16):
100
= software-version
= max. current power source
300
= current nominal value
• green illuminated push button S2 "PA ON" (3):
lights
• LED signal lamp green H30 "Temperature OK" (9):
lights
• LED signal lamp green H29 "Coolant OK" (7):
lights
• An automated gas purging is started.
• LED signal lamp green H28 "Gas OK" (8):
lights
• LED signal lamp yellow H31 "Cumulative error" (13):
does not light
Unit is ready for operation!
Dial the technology range according cutting chart.
See instruction manual of corresponding gas console.
• Select the necessary plasma regime.
• Adjust plasma - and swirl gases according to the cutting charts.
• Adjust the cutting current with the potentiometer.
• Look at the value shown at the current display (16).
example: device 1
example: Smart Focus
example: 0 V
example: V 1.00
example: A
example: 300 A
9