After screwing off the protective cap to replace the swirl gas cap without any further
replacement of consumables, the tightness of the nozzle cap must absolutely be checked
and, if required, tightened again before mounting the protective cap!
apply to plasma torch:
PerCut 2000
PerCut 4000
PerCut 4000 XS
Pos : 3.25 /War nung, Vorsic ht, Ver bot, Gebot, Hinweis/Gebotsz eichen (bl au) /Auf Vollständigkeit der Versc hleißteile achten @ 0\mod_1200055848051_19.doc x @ 2782 @ @ 1
Make sure that all wearing parts are complete and correct installed!
Especially the cooling tube has to be inserted. Other wise the cooling is ineffective and the
torch gets damaged.
No other parts as mentioned before have to be changed unauthorised on the plasma
machine torch.
A further opening of the torch from the front side is not possible.
Pos : 3.26 /War nung, Vorsic ht, Ver bot, Gebot, Hinweis/Warnung ( orange) / Rettungsz eichen (grün) /Dichtheit des Plas mabr enners @ 1\mod_1222083258875_19.doc x @ 5409 @ @ 1
You have to mind on tightness of the plasma torch after consumable change, coolant does
not leave!
Pos : 3.27 /War nung, Vorsic ht, Ver bot, Gebot, Hinweis/Warnung ( orange) / Rettungsz eichen (grün) /Entl adungsr aum z wisc hen Katode und D üs e @ 1\mod_1222083434736_19.doc x @ 5413 @ @ 1
The discharge chamber between cathode and nozzle has to be blown absolutely dry
(press tumbler switch "gas test" approx. 20 seconds - see "operation sequences")