5.
Tumbler switch "Gas test"
upper position: gas test ON
• for adjusting the gas pressure
• for blowing out of the remaining drops of coolant after change of consumables
• LED signal lamp yellow H31 "cumulative error" (13) ON
• plasma cutting system not ready for operation cutting
6.
Tumbler switch "Gas pressure test"
Upper switch position: Gas pressure test ON
• LED signal lamp yellow "cumulative error" (13) and "Process error" (14) are ON
• solenoid valves are closed
• plasma cutting machine is not ready for cutting
Carry out the gas pressure test corresponding to the chapter "Maintenance special".
7.
LED-signal lamp green H29 "Coolant OK"
• LED ON:
8.
LED-signal lamp green H28 "Gas OK"
• LED ON:
cooling circuit operates (flow rateis o. k.)
pressure of plasma and swirl gases and also for control gas,
seecorresponding instruction manual of the gas console