❸ Installing A Ph Link Or Dual Link Module; I Installing The Pod Kit - Zodiac GenSalt OT Series Instructions For Installation And Use Manual

Salt water chlorinator, ph/redox regulation
Hide thumbs Also See for GenSalt OT Series:
Table of Contents

Advertisement

❸ Installing a pH Link or Dual Link module

3.1 I Installing the POD kit

The POD Kit is a measuring chamber using patented Quick Fix® technology for installati on on a rigid 50 mm PVC pipe
(with supplied adapter) or 63 mm PVC pipe (without adapter). It contains the following components:
3.1.1 Recommended locati on
• The cell bypass valves must always be open.
• The sensor-holding POD kit must always be positi oned on a horizontal pipe so that the sensors
are verti cal.
• The POD kit must be the fi rst unit fi tt ed aft er the pool fi lter.
• If the pool is fi tt ed with an electric heater, the POD kit must be installed before it (to take
readings on unheated water).
• We recommend positi oning the POD kit more than 20 cm from an elbow in the pipe.
• The sensor cables must not be positi oned near high voltage mains electricity cables.
Pool Earth
recommended
In line installati on
Pool Earth
recommended
Installati on with heati ng system
: The fl ow switch
: The pH sensor
: The ORP sensor
: pH minus injecti on
Pool Earth
recommended
By-pass installati on
If an electric heater is installed (and not
a heat pump), put the POD Kit in front
of it (to measure unheated water). In
this case, the fl ow rate detector must be
placed in the by-pass on the coverage
clamp.