6.2 I Checking and cleaning the electrodes

The appliance is equipped with a smart polarity reversal system designed to prevent the electrode plates
from scaling. The durati on of the polarity reversal can be changed, see "5.2.11 Setti ng the durati on of
polarity reversal". However cleaning may be required in regions where the water is very hard.
• Turn off the chlorinator and the fi ltering, close the isolati on valves, remove the protecti on cover and
disconnect the cell power cable.
==> eXO® (iQ) cell :
• Unscrew the ti ghtening ring and remove the cell, see illustrati on
a lever to be used in the event of it jamming. Immerse the part which contains the electrode plates in a
suitable container with the cleaning soluti on.
==> GenSalt OT cell :
• Place the cell backwards and fi ll it with a cleaning soluti on so that the electrode plates are immersed.
eXO® (iQ) cell
• Leave the cleaning soluti on to dissolve the scaling for about 15 minutes. Dispose of the cleaning soluti on at
an approved waste recycling site, never pour into the rainwater drainage system or into the sewers.
• Rinse the electrode using clean water and put it back on the cell fi xture collar (there is an alignment
foolproofer).
• Refi t the ti ghtening ring, reconnect the cell cable and refi t the protecti ve cover.
• Open the isolati on valves, then restart the fi ltering and chlorinator.
If you do not use an off the shelf cleaning soluti on, you can make your own by
carefully mixing one part of hydrochloric acid in nine volumes of water (Cauti on: always pour
the acid into the water and not the opposite and wear suitable protecti ve equipment!).
. The ring is crenelated thus allowing