INSTALLATION MANUAL EL Series Saltwater Chlorinator (all models) WARNING FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is qualified in pool equipment in accordance with the latest applicable version of AS/NZS 3000: 2018, along with any other applicable local and national installation codes/standards”, and any other local applicable...
Page 2
Page 2 EL Series Saltwater Chlorinator | Installation Manual For full warranty terms and conditions and to register your warranty, simply visit www.zodiac.com.au/warranty complete your details. Or scan the QR code and be taken directly to the registration page Record your Equipment details here for quick reference: Model No.:...
Page 4 EL Series Saltwater Chlorinator | Installation Manual Section 1. Important Safety Instructions READ AND FOLLOW ALL INSTRUCTIONS All electrical work must be performed by a qualified installer and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precautions should always be...
Page 5
Page 5 EL Series Saltwater Chlorinator | Installation Manual WARNING People with infectious diseases should not use a spa or hot tub. To avoid injury, exercise care when entering or exiting the spa or hot tub. Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning.
Page 6 EL Series Saltwater Chlorinator | Installation Manual Dimensions Section 2. System Overview 2.3.1 Controller Contents 13.15 cm 22.54 cm Before starting, check that you have the correct parts as indicated in Table 1. If any parts are missing or incorrect, please call your local distributor or technical support at 1300 763 021 for assistance.
Page 7 EL Series Saltwater Chlorinator | Installation Manual Section 3. Plumbing The cell must be plumbed in a position that is accessible for maintenance and within 1.5 meters of the controller. The cell should be the last piece of equipment in the circulation system. The cell must be installed horizontally, level and with correct fl ow orientation, see Figure 3.
Page 8 EL Series Saltwater Chlorinator | Installation Manual Section 4. Install Controller Electrical Connections The controller should be located at or near the WARNING equipment pad, at least 3.5 metres or more away FOR YOUR SAFETY: This product must be from the inside wall of the pool/spa, 1.5 metres off...
Page 9 EL Series Saltwater Chlorinator | Installation Manual Section 5. Prepare and Balance the Pool Water Chemistry Table Test and maintain correct water balance throughout the season, according to the table. Free Total Alkalinity Calcium Hard- Cyanuric Acid Salt...
Page 10 EL Series Saltwater Chlorinator | Installation Manual Section 6. Operation User Interface Overview CAUTION To avoid risk of serious damage to the equipment, ensure that all salt added to the pool has completely dissolved before activating the chlorination function of your system.
Page 11 EL Series Saltwater Chlorinator | Installation Manual Section 7. Installing Equipment 7.1.1 User Operation Modes The user mode buttons enable you to select and to Programming/Timers automatically or manually control the chlorinator/ pump. Functions are as follows: The controller has an internal operating timer that is used to define the length of time for the filter a.
Page 12 EL Series Saltwater Chlorinator | Installation Manual Section 8. Inspecting and Cleaning Section 9. Winterizing the Electrode The chlorinator has a protective system which will limit sanitizer production during unfavorable operating In areas that experience calcium hardness the cell conditions, such as cold water or lack of salt.
If the supply cord is damaged, it must be replaced The EL25/EL35 Saltwater Chlorinator has high by Zodiac ,its service agent or a similarly qualified velocity water with chemicals in it. Some of person in order to avoid a hazard.
Page 14 EL Series Saltwater Chlorinator | Installation Manual Section 11. Troubleshooting When there is an error condition, “ERROR” flashes on the display along with the error code. Fault Indication Possible Cause Solution NO FLOW ► Pump turned off/disconnected or valves ►...
Page 15