Cover mode is activated with a open/close
dry contact, check that the installed cover is
compatible and connected to the chlorinator.
Cover mode will automatically be activated when
the cover is closed. The Cover mode message and
the output percentage are displayed on the screen.
23:04 ON
COVER MODE 10%
Cover mode will stop as soon as the cover is
completely open.
6.2.7
Locking the Controller
The controller can be locked, thus deactivating
the buttons on the user interface panel.
Simultaneously press and hold the
buttons for 3 seconds. This function can be
accessed from any screen/menu.
Locking the controller automatically returns the user to
the home screen. To unlock the controller, press and
hold the
and
buttons for another 3 seconds.
Section 7. Installing and Assigning
Equipment
7.1
NOTE: Suitable for any manually-operated variable
1.
2.
3.
4.
and
7.1.1
Quick Clean is a backwash mode and is used
to quickly start/stop the filter pump in order to
backwash the filter.
1.
2.
For safety reasons, the chlorination is stopped
during the backwash mode. To avoid emptying the
pool, the backwash mode automatically stops after
5 minutes.
7.2
The chlorinator is capable of controlling devices in
addition to the filter pump. The equipment must be
connected to the chlorinator using the appropriate
auxiliary line:
Aux 2: for equipment connected to the low voltage
supply (12/24 V).
The following functions are available in the
AUX/LIGHTS menu:
● Turn the lights or aux equipment on/off
● Program a timer (See section 7.3 for details)
NOTE: To control the light transformer, an additional
1.
2.
3.
EziSalt Saltwater Chlorinator | Installation Manual

Filter Pump

speed pump (i.e., any pump that does not
require a communication cable), you must set
the pump configuration to single speed.
Disconnect power from the chlorinator and
remove the cover and lower housing.
Connect the filter pump to the controller at
the pump connection point in the high voltage
raceway.
Replace the lower housing and cover.
Plug the pump into the socket in the base of
the chlorinator.
Quick Clean
Select YES to activate filtration.
Select NO to stop filtration.

Aux/Lights

switching box is required. Please contact your
local pool care professional for this relay box,
item code WW000222.
Remove the lower housing and cover to
expose the connection bar.
Run the supplied low voltage 2 core wire
through the rubber grommet from the relay
switch box into the terminal bar marked
'AUX 2'.
Push the red pin connector into the relay
switch.