EziSalt Saltwater Chlorinator
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a qualified installer in accordance
with the latest enforced version of AS/NZ 3000 and any other applicable local installation codes.
Before installing this product, read and follow all warning notices and instructions that accompany this
product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can cause serious
injury, property damage, or death.

Advertisement

Table of Contents
loading

Summary of Contents for Zodiac EziSalt

  • Page 1 INSTALLATION MANUAL EziSalt Saltwater Chlorinator WARNING FOR YOUR SAFETY - This product must be installed and serviced by a qualified installer in accordance with the latest enforced version of AS/NZ 3000 and any other applicable local installation codes. Before installing this product, read and follow all warning notices and instructions that accompany this product.
  • Page 2 Page 2 EziSalt Saltwater Chlorinator | Installation Manual For full warranty terms and conditions and to register your warranty, simply visit www.zodiac.com.au/warranty complete your details. Or scan the QR code and be taken directly to the registration page Record your Equipment details here for quick reference: Model No.:...
  • Page 3: Table Of Contents

    Page 3 EziSalt Saltwater Chlorinator | Installation Manual Table of Contents Section 1. Important Safety Instructions ..4 Section 7. Installing and Assigning Equipment ........12 Section 2. System Overview ......6 Filter Pump ..............12 Contents ................6 Aux/Lights..............12 Specifications ..............6 Programming/Timers ...........14...
  • Page 4: Section 1. Important Safety Instructions

    Page 4 EziSalt Saltwater Chlorinator | Installation Manual Section 1. Important Safety Instructions READ AND FOLLOW ALL INSTRUCTIONS All electrical work must be performed by a qualified installer and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precautions should always be...
  • Page 5 Page 5 EziSalt Saltwater Chlorinator | Installation Manual WARNING People with infectious diseases should not use a spa or hot tub. To avoid injury, exercise care when entering or exiting the spa or hot tub. Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning.
  • Page 6: Section 2. System Overview

    Page 6 EziSalt Saltwater Chlorinator | Installation Manual Dimensions Section 2. System Overview 2.3.1 Controller Contents 9.6 cm 31.5 cm Before starting, check that you have the correct parts as indicated in Table 1. If any parts are missing or incorrect, please call your local distributor or technical support at 1300 763 021 for assistance.
  • Page 7: Section 3. Plumbing

    Page 7 EziSalt Saltwater Chlorinator | Installation Manual Section 3. Plumbing The cell must be plumbed in a position that is accessible for maintenance and within 2 meters of the controller. The cell should be the last piece of equipment in the circulation system. The cell must be installed horizontally, level and with correct fl...
  • Page 8: Section 4. Install Controller

    Page 8 EziSalt Saltwater Chlorinator | Installation Manual Section 4. Install Controller Electrical Connections The controller should be located at or near the WARNING equipment pad, at least 3.5 metres or more away FOR YOUR SAFETY: This product must be from the inside wall of the pool/spa, 1.5 metres...
  • Page 9 Page 9 EziSalt Saltwater Chlorinator | Installation Manual LOW VOLTAGE HIGH VOLTAGE Figure 6. Controller Connection Ports NAME TYPE FUNCTION SENS Input Not Used PUMP Input Not Used CELL Output Connection of the electrolysis cell Output Connection of the user interface...
  • Page 10: Section 5. Prepare And Balance The Pool

    Page 10 EziSalt Saltwater Chlorinator | Installation Manual Section 5. Prepare and Balance the Pool Water Chemistry Table Test and maintain correct water balance throughout the season, according to the table. Free Total Alkalinity Calcium Hard- Cyanuric Acid Salt Metal...
  • Page 11: Initial Start-Up

    Page 11 EziSalt Saltwater Chlorinator | Installation Manual Initial start-Up 6.2.4 Boost Mode In some cases, the pool may require a higher than The following setting must be configured at the normal chlorination level such as in cases of high initial start up of the device.
  • Page 12: Section 7. Installing And Assigning Equipment

    Page 12 EziSalt Saltwater Chlorinator | Installation Manual Section 7. Installing and Assigning Cover mode is activated with a open/close dry contact, check that the installed cover is Equipment compatible and connected to the chlorinator. Filter Pump Cover mode will automatically be activated when the cover is closed.
  • Page 13 Page 13 EziSalt Saltwater Chlorinator | Installation Manual Use cable ties to hold in place if necessary, then replace the cover/s. Plug the relay switch box into any available 240V GPO. Plug the light transformer directly into the socket located in the switch box. This will now control the light directly from the chlorinator.
  • Page 14: Programming/Timers

    -FAT TUESDAY -DISCO TECH connection to the external timer is made, turn the controller off then back on again. NOTE: Colour sequence is relevant for Zodiac colour 7.3.3 Filter Pump Programming lights only. If other manufacturers lights are installed the colour selection will vary Press to select “Programming”...
  • Page 15: Reversing

    SWC Adjusting your cell reversal times will result in voiding on time then press of warranty. You must consult with Zodiac on 1300 763 to select the hour for the SWC off 021 or your local pool care professional before making time then press any adjustments.
  • Page 16: Slave Mode

    Page 16 EziSalt Saltwater Chlorinator | Installation Manual Section 8. Help Menu Press to select “Reversing” then press The chlorinator will automatically notify you of any to select set hours then press problems by displaying error messages. To help with the understanding of these messages, the Press to exit.
  • Page 17: Section 9. Inspecting And Cleaning The Electrode

    Page 17 EziSalt Saltwater Chlorinator | Installation Manual Section 9. Inspecting and Cleaning Section 10. Winterizing the Electrode Active winterizing leaves the filter pump and chlorinator running during the winter. However the In areas that experience calcium hardness the cell colder the water temperature the greater the wear electrode will benefit from cleaning.
  • Page 18: Section 11. General Maintenance

    11.2 Maintenance Schedule If the supply cord is damaged, it must be replaced The EziSalt Saltwater Chlorinator incorporates by Zodiac ,its service agent or a similarly qualified moving parts and withstands high velocity water person in order to avoid a hazard.
  • Page 19: Section 12. Troubleshooting

    Page 19 EziSalt Saltwater Chlorinator | Installation Manual Section 12. Troubleshooting When there is an error condition, a message is displayed on the screen and the “INFO” LED flashes. To clear an error message after the condition is resolved: • Press and hold for 4 seconds.
  • Page 20 219 Woodpark Road, Smithfield NSW2164, Australia 1300 763 021 | www.zodiac.com.au © 2020 Zodiac Pool Systems LLC. All rights reserved. ZODIAC is a registered trademark of Zodiac International S.A.S.U., used under license. All other trademarks are the property of their respective owners.