I Technical Specifi Cati Ons - Zodiac GenSalt OT Series Instructions For Installation And Use Manual

Salt water chlorinator, ph/redox regulation
Hide thumbs Also See for GenSalt OT Series:
Table of Contents

Advertisement

1.2 I Technical specifi cati ons
1.2.1 Chlorinator
Nominal chlorine producti on
Nominal output current
Recommended salinity
- min.
Power supply voltage
Electric power
Protecti on index
Flow rate in the cell (minimum/
maximum)
Maximum pressure allowed in the
cell
Operati ng water temperature
1.2.2 Opti onal pH Link or Dual Link modules
Power supply voltage
Peristalti c pump fl ow rate
Maximum back pressure (injecti on)
pH and ORP sensor type
pH correcti on
pH minus dosage
pH sensor calibrati on
ORP sensor tolerances
ORP sensor calibrati on
Sensor cable length
5
eXO® (iQ) 10
GenSalt OT 10
10 g/h
2.8 A
Standard
salinity
Low
2 g/L - 1,6 g/L mini
salinity
pH Link
Extra-low voltage (connected to the control box)
pH minus only (hydrochloric or sulphuric acid)
eXO® (iQ) 18
eXO® (iQ)
GenSalt OT 18
22
18 g/h
22 g/h
3.6 A
5 A
eXO®(iQ) : 4 g/L - 3,3 g/L mini
GenSalt OT : 3,0 g/L mini
110 - 240V
50-60 Hz
200 W maximum
IP43
5m³/h < 18m³/h
2.75 bars
5°C < 40°C
1.2 L/h
1.5 bars
combined (pH = blue / ACL = red)
Proporti onal cyclic
1 or 2 points (pH 4 and pH 7)
10 ppm maximum (shock
/
3 metres
GenSalt OT
eXO® (iQ)
25
35
25 g/h
35 g/h
5 A
7.2 A
/
Dual Link
chlorinati on)
1 point (470 mV)

Hide quick links: