5.3 I Calibrati ng the sensors
5.3.1 Calibrati ng the pH sensor (blue)
The pH sensor may be calibrated in 1 point calibrati on or 2 points (pH 4 and pH 7); 2 point calibrati on is recommended
for more accurate measurement.
Current setpoints are displayed on the Home screen whenever the device is ON.
Current Sensor Measure
• Turn on the device.
• Turn off the pool pump and close valves as necessary to isolate the cell and sensors.
• Press
and browse the menu using the
• Select 1 or 2 point calibrati on (2 point calibrati on is recommended):
• Unscrew the pH sensor from the POD.
• Rinse the end of the sensor with tap water.
• Shake off excess water. Do not touch the glass bulb at the end of the pH sensor.
• Place the pH sensor in the pH 7 soluti on and follow the steps on the display:
• Rinse the end of the sensor with tap water.
• Shake off excess water. Do not touch the glass bulb at the end of the pH sensor.
• Place the pH sensor in the pH 4 soluti on and follow the steps on the display:
• Once calibrati on is complete, replace the sensor on the POD.
• If calibrati on is unsuccessful, see «7.1 I Appliance behaviour».
1 point calibrati on : possible if the pH 7 and pH 4 soluti ons provided are not available.
For this:
- Use a sample of water for which you know the pH value.
- Acti vate the 1 point calibrati on and fi ll in this pH value on the screen:
(if an opti onal pH Link or Dual Link module is installed)
butt ons. Press
Setpoint
to confi rm.