Standby Timer, Read - Barco iCon H250 User Manual

Rs 232 serial communications
Hide thumbs Also See for iCon H250:
Table of Contents

Advertisement

2.22 Standby Timer, Read

Description
Reads the actual Standby Timer value
Command
Command [0]
Command [1]
Returned Data
Unsigned word representing the standby time value:
Data[0] = msb
Data[1] = lsb
range: 180 to 3600 seconds
0 seconds = Standby timer OFF
Example
Reads the actual standby timer value, being \x00 (Timer OFF)
Transmit
Start
Projector address
Command[0]
Command[1]
Checksum
Stop
Receive (acknowledge)
Start
Projector address
Command[0]
Command[1]
Checksum
Stop
Receive (awnser)
Start
Projector address
Command[0]
Command[1]
Data[0]
Data[1]
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400 16/02/2007
\x21
\x98
\xfe
\x01
\x21
\x98
\xba
\xff
\xfe
\x01
\x00
\x06
\x07
\xff
\xfe
\x01
\x21
\x98
\x00
\x00