2.6.27 Gamma, Write

Description
Writes a new Gamma value to the projector
Command
Command [0]
Command [1]
Data
Data [0] = Gamma value
Data[0] = unsigned byte
Example
Writes a new Gamma value of \x11 to the projector
Transmit
Start
Projector address
Command[0]
Command[1]
Data
Checksum
Stop
Receive (acknowledge)
Start
Projector address
Command[0]
Command[1]
Checksum
Stop
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400 16/02/2007
\x20
\x70
\xfe
\x01
\x20
\x70
\x11
\xa2
\xff
\xfe
\x01
\x00
\x06
\x07
\xff