Minimum Brightness, Read - Barco iCon H250 User Manual

Rs 232 serial communications
Hide thumbs Also See for iCon H250:
Table of Contents

Advertisement

2.6.11 Minimum Brightness, Read

Description
Reads the minimum (range) Brightness value of the projector
Command
Command [0]
Command [1]
Returned Data
Data [0] = minimum Brightness value
Example
Reads the minimum Brightness value of the projector, the awnser being \x00
Transmit
Start
Projector address
Command[0]
Command[1]
Checksum
Stop
Receive (acknowledge)
Start
Projector address
Command[0]
Command[1]
Checksum
Stop
Receive (Answer)
Start
Projector address
Command[0]
Command[1]
Data [0]
Checksum
Stop
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400 16/02/2007
\x26
\x02
\xfe
\x01
\x26
\x02
\x29
\xff
\xfe
\x01
\x00
\x06
\x07
\xff
\xfe
\x01
\x26
\x02
\x00
\x29
\xff
2. Basic commands
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icon h400

Table of Contents