Projector's Status, Read - Barco iCon H250 User Manual

Rs 232 serial communications
Hide thumbs Also See for iCon H250:
Table of Contents

Advertisement

2.4

Projector's Status, Read

Description
Reads the Projector's Status
Command
Command [0]
Returned Data
Data [0] = unsigned byte
bit7
bit6
Not used
Not used
bit5 gives an indication on whether the projector can be (re)started or not (hot restrike), if the cool down cycle
is active (bit5 = 0) the projector can not be restarted until the cool down cycle has been completed.
Example
Read the status being : \x23:
projector is ON
textbox is on
cool down cycle is inactive
Transmit
Start
Projector address
Command[0]
Checksum
Stop
Receive (acknowledge)
Start
Projector address
Command[0]
Command[1]
Checksum
Stop
Receive (Awnser)
Start
Projector address
Command[0]
Data[0]
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400 16/02/2007
bit5
bit4
Cool down cycle
Not used
active = 0
inactive = 1
\x67
bit3
bit2
Not used
Not used
\xfe
\x01
\x67
\x68
\xff
\xfe
\x01
\x00
\x06
\x07
\xff
\xfe
\x01
\x67
\x23
2. Basic commands
bit1
bit0
Textbox
Projector
ON = 1
ON = 1
OFF = 0
OFF = 0
23