Rs 232 serial communications
Hide thumbs Also See for iCon H250:
Table of Contents

Advertisement

2. Basic commands
2.8

Background, Write

Description
Sets a particular background.
Command
Command [0]
Command [1]
Data
Data [0] = unsigned byte
byte value:
\x02 = Black ; \x03 = iCon Server
Example
Sets the background to "Black"
Transmit
Start
Projector address
Command[0]
Command[1]
Data[0]
Checksum
Stop
Receive (acknowledge)
Start
Projector address
Command[0]
Command[1]
Checksum
Stop
68
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400 16/02/2007
\x20
\x7B
\xfe
\x01
\x20
\x7b
\x02
\x9e
\xff
\xfe
\x01
\x00
\x06
\x07
\xff

Advertisement