End of process (EOP)

When the end of process command is activated, an EOP is send after the ACK command to signify the completion of the process.
for more information about this, see the EOP command.
Note
Any command byte, data byte or checksum byte that equals \x80, \xfe, \xff has to be converted !
1.
Transmission
-
instead of \x80, send \x80 followed by \x00
-
instead of \xfe, send \x80 followed by \x7e
-
instead of \xff, send \x80 followed by \x7f
2.
Reception
-
replace \x80 followed by \x00 with \x80
-
replace \x80 followed by \x7e with \xfe
-
replace \x80 followed by \x7f with \xff