2.6.17 Minimum Saturation, Read
Description
Reads the minimum (range) Saturation value of the projector
Command
Command [0]
Command [1]
Returned Data
Data [0] = minimum Saturation value
Example
Reads the minimum Saturation value of the projector, the awnser being \x00
Transmit
Start
Projector address
Command[0]
Command[1]
Checksum
Stop
Receive (acknowledge)
Start
Projector address
Command[0]
Command[1]
Checksum
Stop
Receive (Answer)
Start
Projector address
Command[0]
Command[1]
Data [0]
Checksum
Stop
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400 16/02/2007
\x26
\x03
\xfe
\x01
\x26
\x03
\x30
\xff
\xfe
\x01
\x00
\x06
\x07
\xff
\xfe
\x01
\x26
\x03
\x00
\x30
\xff
2. Basic commands
47