9 Important Circuit Information
9.3 Axis expansion using the monitoring module
9.3.2
Instantaneous
shutdown
Delayed shutdown
9
1) Settings, S1.2 ready/fault signal, refer to Section 6.1.
2) The shutdown is shown in a simplified fashion without any contacts of the drive–related control
3) Time relay with delayed drop–out with auxiliary function, e.g. 3RP1505–1AP30,
t
> max. braking time of the drive after the monitoring module.
(v)
9-234

Connection example, pulse enable

NE module
S1.2
Ready/
fault message
1)
0 V
To the external power supply
Fig. 9-6
Instantaneous shutdown, pulse enable
NE module
S1.2
Ready/
fault message
1)
+24 V
–KT
3)
0 V
To the external power supply
Fig. 9-7
Delayed shutdown, pulse enable
72
73.1
FR– 19
72
–KT
73.1
FR– 19
1
B1
3
B3
15
A
A
2
16
A
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
Monitoring module
9 FR+
2)
63 IF
S1.2
Ready/
fault message
1)
19 FR–
Monitoring module
15
9 FR+
2)
63 IF
18
S1.2
Ready/
fault message
1)
19 FR–
18
 Siemens AG 2001 All rights reserved