Siemens SIMODRIVE 611 Planning Manual page 201

Drive converter
Hide thumbs Also See for SIMODRIVE 611:
Table of Contents

Advertisement

05.01
Connection types, pulsed resistor module
Pulsed resistor
module
Fig. 6-16
Note
For pulsed resistor modules, only the external pulsed resistor 1.5/25 kW can be
connected.
The following connection combinations are possible:
Fig. 6-17
Number of pulsed resistor modules connected to the same DC link, refer to
Catalog NC60
NvC / 500 µF
N = max. number of pulsed resistor modules (must always be rounded–off)
C = DC link capacitance of the drive group in µF
 Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
Pul-
sed
resi-
stor
mo-
dule
P600
M600
3R
2R
1R
Status of the pulsed resistor module when supplied
Connection of an external 1.5 kW resistor:
Connector without jumper
Internal resistor is inactive
External resistor is active
1) Shield connection as close as possible to the
module
Order number: 6SN1113–1AB0V–0VAV
Pul-
sed
resi-
stor
mo-
dule
P600
M600
3R
2R
1R
PE rail
Connecting an external 1.5 kW pulsed resistor
6 Infeed Modules
6.6 DC link options
Status as supplied:
Connector with jumper between 1R and
2R
Internal resistor active
Order number: 6SN1113–1AB0V–0VAV
3R
PE
1R
1)
6
6-201