Preparing before you go on-site

1. Check Juniper software compatibility with TGM550 Gateway Module
firmware. See http://support.avaya.com.
2. Download the most recent firmware for the TGM550. See
support.avaya.com.
3. Ensure the customer has an FTP or TFTP server that is accessible to the
TGM550. If not, download a TFTP server to your laptop.
4. Review safety requirements and airflow requirements. See Installing and
Configuring the IG550 Integrated Gateway.
5. Get the tools you need:
Electrostatic discharge (ESD) grounding strap
Flathead and Phillips head screwdrivers

Getting ready on-site

1. Verify you have:
The Juniper Services Router (J2320, J2350, J4350 or J6350)
A 10 AWG grounding cable
An AC or 14 AWG DC power cable
Cables for the TGM550, Telephony Interface Modules (TIMs), and
Physical Interface Modules (PIMs)
!
CAUTION:
You cannot use a 14 AWG grounding cable with the router. The
CAUTION:
grounding cable must be 10 AWG.
A USB modem
Two distinct and different console cables:
- An RJ-45 flat rollover cable and a DB-9 adapter for console
connections to the TGM550
- An ordinary round RJ-45 Ethernet cable and a DB-9 adapter for
console connections to the Juniper router