TIM510 T1/E1 — H600-383 Group 2 T1 cable with an RJ48C
●
connector
TIM514 — CAT5 cable with an RJ11 connector
●
TIM516 — A B25A unshielded 25-pair amphenol cable
●
TIM518 — A B25A unshielded 25-pair amphenol cable
●
TIM521 — CAT5 cable with an RJ45 connector
●
Juniper PIMs, EPIMs, and UPIMs — see Juniper J2320, J2350, J4350,
●
and J6350 Services Router Getting Started Guide, Release 8.4
7. For the TIM508, TIM516, or TIM518, use the screw at the end of the
Amphenol connector to attach the connector to the left side of the TIM's
Amphenol receptacle. Use a tie wrap to attach the cable to the tie wrap
loop to the right of the Amphenol receptacle on the TIM.
8. Connect the grounding cable to earth ground and the chassis grounding
point. Specifications include:
10 AWG
●
Minimum 8 Amps amperage
●
Ring-type, vinyl-insulated TV14-6R lug or equivalent to accommodate
●
the
10 AWG cable
J4350 or J6350 ground -
qsmagnd3 LAO 092906
J2320 or J2350 ground -
Issue 2 January 2008