Weidmuller UR20-4DI-4DO-PN-FSOE Manual page 62

Remote i/o system u-remote; modules for functional safety
Table of Contents

Advertisement

5 Detailed descriptions of safe modules | Safe power-feed module UR20-PF-O-2DI-SIL
Technical data UR20-PF-O-2DI-SIL (Order No. 1335050000)
Diagnosis
Module diagnosis
Individual channel diagnosis
Supply
Supply voltage
External pre-fusing
Reverse battery protection
Current consumption from system current path I
Current consumption from input current path I
General data
Weight (operational status)
Additional general data, see Section 5.1.
Process data UR20-PF-O-2DI-SIL
Byte
Bit definition
0
1
2
3
0
4
5
6
7
0
1
1
2
3 ... 7
2
0–7
3
0–7
62
SYS
IN
Description
Safety input 0
Safety input 1
Automatic start
Manual start
Safety input 0, channel 1
Safety input 0, channel 2
Safety input 1, channel 1
Safety input 1, channel 2
24 V Safe output
Reserved
24 V DC feed-in
Reserved
Reserved
Reserved
u-remote IP20 modules for functional safety manual
yes
yes
24 V DC +20 %/-15 %
Mandatory: super fast, max. 8 A
yes
8 mA
45 mA
82 g
Status
0 - inactive, 1 - active
0 - inactive, 1 - active
0 - inactive, 1 - active
0 - inactive, 1 - active
0 - inactive, 1 - active
0 - inactive, 1 - active
0 - inactive, 1 - active
0 - inactive, 1 - active
0 - inactive, 1 - active
0 - no feed-in, 1 - power feed-in pending
Conncection
S 11 ... S 22
S 31 ... S 42
Autostart 1/2
Man Start 1/2
S 11/S 12
S 21/S 22
S 31/S 32
S 41/S 42
24 V Safe
24 V
1484600000/04/06.2017