5 Detailed descriptions of safe modules | Digital in- and output module UR20-4DI-4DO-PN-FSPS, UR20-4DI-4DO-PN-FSPS-V2
Overview of the editable parameters
Channel
Description
2
Input delay
2
Test pulse
2
Input polarity
3
Input delay
3
Test pulse
2 + 3
Input dual channel mode (inputs 2 + 3)
2 + 3
Discrepancy time
4 ... 5
Test pulse
4 ... 5
Output test pulse duration (output 0 ... 1)
4
Output polarity
4 + 5
Output dual channel mode (outputs 0 + 1)
6 ... 7
Test pulse
6 ... 7
Output test pulse duration (output 2 ... 3)
6
Output polarity
6 + 7
Output dual channel mode (outputs 2 + 3)
1) Please regard the notes for parameter settings.
Notes for parameter settings
– The module independently performs a plausibility test for
the relevant pair of inputs or outputs, if the dual channel
mode is parameterised. On this it will be checked if both
inputs or outputs become active or inactive simultane-
ously within the discrepancy time.
– The "test pulse" parameter of an input must be disabled
(V1 variant) or set "external" (V2 variant) if a safety device
with OSSD outputs generating own test pulses is con-
nected. The test pulse duration depends on the parame-
terised input delay:
Input delay [ms]
Test pulse duration [ms]
44
UR20-4DI-4DO-PN-FSPS-V2
1)
Options
1 ms (0) / 3 ms (1) / 10 ms (2) / 100 ms (3)
internal (0) / external
P-switching (0) / N-switching (1)
1 ms (0) / 3 ms (1) / 10 ms (2) / 100 ms (3)
internal (0) / external
single channel (0) / dual channel equivalent (1) / dual channel antivalent (2)
5 ... 30.000 ms
disabled
(0) / enabled (1)
1)
0.5 ms (0) / 1 ms (1) / 3 ms (2) / 10 ms (3)
P-switching (0) / N-switching (1)
single channel (0) / dual channel (1)
disabled
(0) / enabled (1)
1)
0.5 ms (0) / 1 ms (1) / 3 ms (2) / 10 ms (3)
P-switching (0) / N-switching (1)
single channel (0) / dual channel (1)
1
3
10
100
0.5
1
3
u-remote IP20 modules for functional safety manual
(1) / from AUX2 (2) / from AUX3 (3)
1)
(1) / from AUX3 (3)
1)
– Please regard the following when parameterising „exter-
nal" test pulses with a UR20-4DI-4DO-PN-FSPS-V2 mod-
ule:
– An edge transition must occur at least every five min-
utes at an active input. Otherwise a module error will
be signalised.
– With this setting the module cannot detect any short
circuits. The short circuit detection must be realised by
the connected OSSD device.
Please regard the following to ensure that the safety func-
10
tion will not be influenced.
– In the event that the output test pulses of a
UR20-4DI-4DO-PN-FSOE-V2 module are disabled output
errors will only be detected under the following condi-
tions:
– No filament lamp load must be connected.
– The capacitive load at this output may be 250 µF at
maximum.
Default
1 ms
internal
P-switching
1 ms
internal
single channel
500 ms
disabled
0.5 ms
P-switching
single channel
disabled
0.5 ms
P-switching
single channel
ATTENTION