Connecting the server to the ELAN subnet

Introduction

Connect the CallPilot server to the Meridian 1 switch or Avaya Communication Server 1000
system using the ELAN subnet.
Note:
If you are installing a High Availability system, do not connect either sever to the ELAN
subnet. The connection to the ELAN subnet is made when you configure the system.
Important:
For important considerations about using the ELAN subnet in your network, see the Planning
and Engineering Guide (NN44200-200).
Important:
To comply with EMC radiation requirements, a Class A Ethernet switch or hub must be
located 10 m (33 ft.) away from the 1005r server. You must use shielded Ethernet cables.
To connect the server to the ELAN subnet
1. See the diagram on page
2. Connect an RJ-45 network cable from the ELAN Ethernet switch or hub to the ELAN
3. At the switch, connect the ELAN network cable to the ELAN Ethernet interface.
Avaya CallPilot® 1005r Server Hardware Installation
Ethernet connector.
connector on the server.
Note:
The ELAN Ethernet switch or hub is optional if you use a cross-over network
cable to make a direct point-to-point connection from the server to the switch.
However, if you choose to establish a direct point-to-point ELAN connection, no
other device can connect to the ELAN subnet.
Complete the connection from the transceiver to the switch.
Danger:
Risk of fire hazard
Do not install a Media Access Unit (MAU) in ducts, plenums, or other spaces
used for environmental air. Do not install a MAU above a false ceiling or below a
Connecting the server to the ELAN subnet
Rear panel connectors
on page 34 to locate the ELAN