Omron NJ Series Startup Manual page 39

Machine automation controller
Hide thumbs Also See for NJ Series:
Table of Contents

Advertisement

Setting the Axis Parameters
Set the axis parameters for axis 0 based on the mechanical configuration of the system.
The input axis parameters are shown in the following table according to the mechanical configuration of
axis 0.
Icon on Settings Tab Page
Unit Conversion Settings
Operation Settings
Position Count Settings
1
Set the parameters on the Axis Parameter Settings Tab Page.
Click an icon on the Axis Parameter Settings Tab Page to display the settings for that particular
icon.
Set the axis parameters as indicated below.
• Unit Conversion Settings
NJ/NX-series Startup Guide for Motion Control (W514)
3 Setting Up a Single-axis Servo System
Item
Unit of Display
Command Pulse Count Per Motor
Rotation
Work Travel Distance per Motor
Rotation
Maximum Velocity
Maximum Jog Velocity
Encoder type
Set value
mm
8,388,608
10.000 mm
500 mm/s
50 mm/s
Absolute encoder
3-13
3