3 Setting Up a Single-axis Servo System
3-7-3

Checking the Servo Drive Wiring

Use the MC Test Run operation in the Sysmac Studio to check the wiring of the Servo Drive.
The wiring is checked in PROGRAM mode to prevent a user program for which operation has not been
verified from affecting the wiring confirmation results. In this Guide, the project is transferred in PRO-
GRAM mode.
An MC Test Run allows you to perform tasks such as monitoring the control inputs of an OMRON Servo
Drive that has been assigned to an axis or operating the Servomotor without any user programming.
Use this to check the Servo Drive wiring and the operation of the Servomotor.
Starting an MC Test Run
Start an MC Test Run from the Sysmac Studio.
1
Right-click MC_Axis000(0) under Configurations and Setup - Motion Control Setup - Axis
Settings in the Multiview Explorer, and select Start MC Test Run from the menu.