Wiring Safety Points; Start-Up And Maintenance Safety Points - Omron SCARA YRC Series Supporting Supplement Manual

Hide thumbs Also See for SCARA YRC Series:
Table of Contents

Advertisement

2.3

Wiring safety points

WARNING
• ALWAYS SHUT OFF ALL PHASES OF THE POWER SUPPLY EXTERNALLY BEFORE STARTING INSTALLATION OR
WIRING WORK. FAILURE TO SHUT OFF ALL PHASES MAY CAUSE ELECTRICAL SHOCK OR PRODUCT DAMAGE.
CAUTION
• Make sure that no foreign matter such as cutting chips or wire scraps enter the robot controller. Malfunctions, breakdown or fire may
result if they have entered.
• Always store the cables connected to the robot controller in a conduit or clamp them securely in place. If the cables are not stored in
a conduit or properly clamped, excessive play or movement or mistakenly pulling on the cable may damage the connector or cables,
and poor cable contact may cause equipment malfunctions.
• Do not modify the cables and do not place any heavy object on them. Handle them carefully to avoid damage. Damaged cables may
cause malfunction or electrical shock.
• If there is a possibility that the cables connected to the robot controller may be damaged, protect them with a cover, etc.
• Do not apply excessive loads or impacts to the connectors when making cable connections. The connector pins may become bent or
the internal PC board may be damaged.
• When disconnecting the cable from the robot controller, detach by gripping the connector itself and not by tugging on the cable.
Loosen the screws on the connector (if fastened with the screws), and then disconnect the cable. Detaching by pulling on the cable
itself may damage the connector or cables, and poor cable contact may cause equipment malfunctions.
2.4

Start-up and maintenance safety points

DANGER
• NEVER ENTER THE ROBOT'S WORKING ENVELOPE WHILE THE ROBOT IS OPERATING OR THE MAIN POWER IS
TURNED ON. FAILURE TO FOLLOW THIS INSTRUCTION MAY CAUSE SERIOUS ACCIDENTS INVOLVING INJURY OR
DEATH. INSTALL A SAFETY ENCLOSURE OR A GATE INTERLOCK WITH AN AREA SENSOR TO KEEP ALL PERSONS
AWAY FROM THE ROBOT'S WORKING ENVELOPE.
• WHEN IT IS NECESSARY TO OPERATE THE ROBOT WHILE YOU ARE WITHIN THE ROBOT MOVEMENT RANGE
SUCH AS FOR TEACHING OR MAINTENANCE/INSPECTION TASKS, ALWAYS CARRY THE PROGRAMMING BOX
WITH YOU SO THAT YOU CAN IMMEDIATELY STOP THE ROBOT OPERATION IN CASE OF AN ABNORMAL OR
HAZARDOUS CONDITION. INSTALL AN ENABLE DEVICE IN THE EXTERNAL SAFETY CIRCUIT IS NEEDED. ALSO
SET THE ROBOT MOVING SPEED TO 3% OR LESS. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY CAUSE
SERIOUS ACCIDENTS INVOLVING INJURY OR DEATH.
• CHECK THE FOLLOWING POINTS BEFORE OPERATING THE ROBOT:
• NO ONE IS WITHIN THE ROBOT'S WORKING ENVELOPE.
• THE PROGRAMMING BOX IS AT THE SPECIFIED POSITION.
• THERE IS NO ABNORMAL STATE IN THE ROBOT AND RELATED DEVICES.
WARNING
• ONLY PERSONNEL TRAINED IN SAFETY AND ROBOT OPERATION MAY OPERATE THE ROBOT. OPERATION BY ANY
PERSON WHO HAS NOT RECEIVED THE PROPER TRAINING IS VERY DANGEROUS AND MUST BE AVOIDED.
• THE ROBOT AND ROBOT CONTROLLER ARE NOT DESIGNED TO BE EXPLOSION-PROOF. DO NOT USE THEM IN
LOCATIONS EXPOSED TO INFLAMMABLE GASES, GASOLINE OR SOLVENT THAT COULD CAUSE EXPLOSION OR
FIRE. FAILURE TO FOLLOW THIS INSTRUCTION MAY CAUSE SERIOUS ACCIDENTS INVOLVING INJURY OR DEATH,
OR LEAD TO FIRE.
• DO NOT TOUCH ANY ELECTRICAL TERMINAL OF THE ROBOT CONTROLLER. DOING SO MAY CAUSE ELECTRICAL
SHOCK OR EQUIPMENT MALFUNCTIONS.
• ALWAYS CONNECT THE ROBOT AND ROBOT CONTROLLER IN THE CORRECT COMBINATION. USING THEM IN AN
INCORRECT COMBINATION MAY CAUSE FIRE OR BREAKDOWN.
• ALWAYS SHUT OFF ALL PHASES OF THE POWER SUPPLY EXTERNALLY BEFORE CLEANING OR TIGHTENING THE
TERMINAL SCREWS. FAILURE TO SHUT OFF ALL PHASES MAY CAUSE ELECTRICAL SHOCK, PRODUCT DAMAGE
OR MALFUNCTIONS.
• DO NOT TOUCH THE ROBOT CONTROLLER AND ROBOT DURING OPERATION. SOME PARTS IN THE ROBOT
CONTROLLER OR ROBOT ARE HOT DURING OPERATION. TOUCHING THEM MAY CAUSE BURNS.
• DO NOT HANDLE OR OPERATE THE ROBOT CONTROLLER OR PROGRAMMING BOX WITH WET HANDS. TOUCHING
THEM WITH WET HANDS MAY RESULT IN ELECTRICAL SHOCK OR BREAKDOWN.
• IMMEDIATELY TURN OFF POWER IF UNUSUAL ODORS, NOISE OR SMOKE ARE NOTICED DURING OPERATION.
CONTINUOUS OPERATION UNDER SUCH A CONDITION MAY RESULT IN ELECTRICAL SHOCK, FIRE OR
BREAKDOWN. STOP USING AND CONTACT OUR SALES OFFICE OR SALES REPRESENTATIVE.
3

Advertisement

Table of Contents
loading