2. Fitting
1
The electrical
connection of the
system supply
points upwards
2
Tie rods
3
Tie rod groove
Fig. 2/7: CPX terminal (rear view)
Festo P.BE−CPX−SYS−EN en 0503b
Caution
When sub−bases are arranged in series:
Make sure that the electric plug connectors of the manifold
sub−bases are not bent.
3. Align the CPX terminal on a flat surface so that the compo
nents are not offset.
In the case of CPX terminals without pneumatics or with
CPA pneumatics, you can place the CPX terminal so that
the electrical connections for the system supply and, if
applicable, for the additional supply point upwards. The
tie rod is held in the tie rod groove by the weight force.
1
4. Press the manifold sub−bases together carefully and with
out tilting.
5. Place the end plate on the tie rod.
6. Make sure that the screw connectors are seated correctly
and carefully screw the tie rod screws a few turns into the
tie rods.
7. Then tighten the screws equally with a hexagon socket
wrench size 3 max. 2 Nm ± 0.3 Nm.
2
3
2−15