B. Parameters and data of the CPX terminal
Module parameters: Monitoring the CPX module
Modules
Depending on the monitoring function for modules with digital and analogue
inputs and outputs (see description on the respective module)
Function no.
4828 + m * 64 + 0
Description
For each module the monitoring of the possible faults can be activated or deacti
vated (suppressed) independently of each other. Active monitoring causes the
following: The fault is:
Monitoring
Bit
Description
0
Short circuit/overload in sensor supply
1
Short circuit/overload at the outputs
2
Undervoltage at outputs/valves (V
3
Short circuit at the valve
4
Reserved
5
Reserved
6
Reserved
7
Monitoring parameterisation faults
Values
1 = Active (presetting)
0 = Inactive
Note
Monitoring can also be set for the complete CPX terminal
(see system parameter Monitoring").
Tab. B/11: Monitoring the CPX module
B−16
sent to the CPX field bus node
displayed by the module common error LED.
For parametrizing the Monitoring CP modules" on the
CPX−CP interface see the manual for the CPX−CP interface
typeP. BE−CPX−CP−... .
m = module number (0...47)
)
OUT/VAL
Festo P.BE−CPX−SYS−EN en 0503b
[Monitor]
[Monitor SCS]
[Monitor SCO]
[Monitor V
]
OUT/VAL
[Monitor SCV]
[Monitor parameters]
[Active]
[Inactive]