B. Parameters and data of the CPX terminal
Diagnostic memory parameters: Module/channel filter
Function no.
3484
Description
With this diagnostic memory filter, the registering of faults of other modules or
channels can be suppressed in order that faults in a particular module or channel
can be analysed.
Bit
Bits 6, 7
Values
Module/channel filter
FN = fault number
Bit 7 6
Description
0 0
Module/channel filter inactive (presetting)
0 1
Register only the FN of a module
1 0
Register only the FN of a channel
1 1
Reserved
Note
The numbers are determined by means of the diagnostic memory parameters
Module and channel numbers" (function nos. 3485...3486).
Tab. B/28: Module/channel filter
Diagnostic memory parameters: Module number (MN)
Function no.
3485
Description
Module number for the diagnostic memory filter
Bit
0...7
Values
Module number (MN)
0...47
Note
Is only effective if an appropriate diagnostic memory filter is active.
Tab. B/29: Module number (MN)
Festo P.BE−CPX−SYS−EN en 0503b
(1 byte)
Module number (0 = presetting)
[Module/channel filter]
[Inactive]
[Rec. FN of a mod.]
[Rec, FN of a ch.]
[Module number MN]
B−27