2-3 TERMINAL

<Transmitter>
POWER INPUT
(1) +
10.5-30VDC [ Normal ]
(2) -
*
3.6VDC [ SBU-4 ]
(3)
SPARE
(4)
(5)
ALARM INPUT
(6)
(7)
LOW BATTERY
INPUT
(using with SBU-4)
(8)
TAMPER
(9)
OUTPUT (N.C.)**
Note>>
Connect POWER INPUT
ALARM MEMORY INPUT terminal(11) and LOW BATTERY INPUT terminal(12) of the receiver.
*
SBU-4 and its low battery input/output function not evaluated by UL

2-4 WIRING DIAGRAM

1
1 Set
Connect the power supplies in parallel.
(1)
(2)
(1)
Transmitter
*1 CONTROL PANEL = UL/c-UL listed burglar alarm control panel
*2 POWER = power limited output
3
2 Sets in the line
Connect the power supply in parallel. Connect the units serially for a normally closed alarm output and in parallel for a normally open output
(the figure below shows an example for a normally closed alarm output).
(1)
(2)
(1)
Transmitter
SL-QDM
<Receiver>
POWER INPUT
(1) +
10.5-30VDC [ Normal ]
(2) -
3.6VDC [ SBU-4 ]
(3)
SPARE
(4)
(5) N.O.
D.Q. OUTPUT/
(6) N.C.
LOW BATTERY
(7) COM.
OUTPUT* **
(8) COM.
*
ALARM OUTPUT**
(9) N.C.
(10) N.O.
(11)
ALARM MEMORY INPUT
LOW BATTERY INPUT
(12)
(using with SBU-4)
(13)
TAMPER OUTPUT**
(14)
(N.C.)
terminal(2) when wiring LOW BATTERY INPUT* terminal(7) of the transmitter,
-
CONTROL PANEL *1
POWER
ALARM
N.C.
(2) (8) (9)
Receiver
(2)
(8) (9)
Receiver
<Transmitter>
(1) +
POWER INPUT
10.5-30VDC
(2) -
*
(3)
SPARE
(4)
*
(5)
TAMPER
(6)
OUTPUT (N.C.)**
** All outputs are power-limited.
2
2 Sets Stacking
Connect the power supply in parallel. Connect the units serially for a
normally closed alarm output and in parallel for a normally open
output (the figure below shows an example for a normally closed
alarm output).
*2
(1)(2)
Ch1
(1) (2)
Ch3
Transmitter
(1) (2) (8) (9)
(1) (2)
Receiver
Transmitter
-5-
SL-QDP
<Receiver>
(1) +
POWER INPUT
10.5-30VDC
(2) -
(3)
SPARE
(4)
(5) N.O.
(6) N.C.
D.Q. OUTPUT
(7) COM.
(8) COM.
ALARM OUTPUT**
(9) N.C.
(10) N.O.
(11)
ALARM MEMORY INPUT
(12)
SPARE
(13)
TAMPER OUTPUT**
(14)
(N.C.)
CONTROL PANEL
POWER
ALARM
N.C.
(1)(2)(8)(9)
Ch1
(1) (2)
(8) (9)
Ch3
Receiver
CONTROL PANEL
POWER
ALARM
N.C.
*1
*2
*1
*2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl-200qdmSl-350qdpSl-350qdmSl-650qdpSl-650qdmSl-200qdp

Table of Contents