Optex SX-360Z Installation Instructions

Optex SX-360Z Installation Instructions

360 ceiling mount passive infrared detector

Advertisement

Quick Links

10
LED ON-OFF
The LED can be enabled or disabled by using the LED ON/OFF
switch or by using D.L. terminal.
1 LED ON/OFF Switch (SX-360Z only)
• Use this switch to enable or disable LED.
• This switch has priority to over DL terminal.
2 DL Terminal (for LED remote control)
• LED can be enabled or disabled remotely by using
DL terminal.
Remote operation
LED Enabled
Connect DL terminal to common ground.
LED Disabled
Open DL terminal circuit.
Note>>
LED operation does not affect the alarm memory functions.
DL terminal common line is same as terminal of POWER INPUT.
12
SPECIFICATIONS
Model
SX-360Z
Passive Infrared
Detection method
Detection zones
276 zones
Mounting location
Celling
Coverage / Mounting
ø18 m (ø60 ft.) at 2.4 –5 m (8 –16 ft.)
height
360° ZOOM
Optical design
LED is blinking during warm-up period.
LED indicator
Alarm condition
Alarm period
2.0 ±0.5 sec.
Alarm output
N.C., 28 VDC 0.2 A (max.)
Tamper switch
N.C., Opens when cover removed.
Tamper output
30 V DC 0.1 A (max.)
Pulse Count
20 ±5 sec. 1, 2 or 4
Approx. 20 sec. (LED blinks.)
Warm up period
Power input
9.5 to 18 VDC
Current draw
16 mA/(normal), 18 mA/(max.)
Weight
224 g (7.90 oz)
Operating
–20°C to +50°C (–4°F to +122°F)
temperature
95% (max.)
Environment humidity
RF interference
No Alarm 30 V/m
13
COMPLIANCE
EMC Directive
(SX-360Z)
2004/108/EC
EN50131-1 Grades and Environmental Class:
EN 50130-4: 2011
Security Grade 2 and Environmental Class II.
EN 55022: 2010
EN 50131-2-2
Tested and certified by Telefication.
PD6662:2010
larm klass 2, miljö klass II, SSF 1014 v4
UL/c-UL Listed
OPTEX CO., LTD. (JAPAN)
URL: http://www.optex.net/
OPTEX INC. (U.S.)
OPTEX TECHNOLOGIES B.V.
(The Netherlands)
URL: http://www.optexamerica.com/
URL: http://www.optex.eu/
OPTEX DO BRASIL LTDA. (Brazil)
OPTEX SECURITY SAS (France)
URL: http://www.optex.net/br/es/sec/
URL: http://www.optex-security.com/
OPTEX (EUROPE) LTD. / EMEA HQ (U.K.)
OPTEX SECURITY Sp.z o.o. (Poland)
URL: http://www.optexeurope.com/
URL: http://www.optex.com.pl/
11
TROUBLE SHOOTING AND MAINTENANCE
PROBLEM
PROBABLE CAUSE
REMEDY
Incorrect power supply voltage.
Correct supply voltage to
(disconnection, or low voltage)
9.5 - 18 VDC.
Incorrect detection area.
See section 2 and section 7.
LED does not light.
Switch positive and negative at
Incorrect polarity to detector.
terminal.
LED switch is OFF
Turn on the Switch. See section 10.
Moving object within area. (curtain,
Remove object from detection
LED lights even
wall hanging, etc.)
area.
though no person
within area.
Rapid temperature changes (heater,
Remove object from detection area.
air-conditioner, etc.) within area.
Poor connection of alarm memory.
Reconnect wire.
(SX-360ZV)
LED continues to
light
Wrong control voltage from panel.
Must be 0 to 1 VDC. (grounded)
(SX-360ZV)
Check load of output. The unit
Relay contact is stuck of damaged
needs repair or replacement.
due to overloading.
LED lights but signal
is not sent.
Faulty Wiring.
Wire correctly.
Model
SX-360ZV
Alarm memory
Armed : 0 to 1 VDC. See section 8.
Initial Alarm memory
Max.40 detectors See section 8.
Current draw
16 mA/(normal), 28 mA/(max)
Weight
227 g (8.00 oz.)
RF interference
No Alarm 30 V/m
Dimensions
Mounting Position
Flush
Flush
wiring space
wiring knockout
Surface
wiring knockout
Pitch ø83.5 (ø3.29)
Mounting
holes
ø6.5 (ø0.26)
Wall tamper knockout
Terminals
8.5 (0.33)
Surface wiring knockout
Flush wiring knockout
12
(0.47)
mm (inch)
* Specifications and design are subject to change without prior notice.
Note>>
• This unit is designed to detect movement of an intruder and activate an
alarm control panel. Being only a part of a complete system, we cannot
accept responsibility for any damages or other consequences resulting
from an intrusion.
• This Product conforms to the EMC Directive. 2004/108/EC.
• The ULC products are installed in accordance with the Canadian Code
as per Section 4.3 of ULC-S306.
OPTEX PINNACLE INDIA, PVT., LTD. (India)
URL: http://www.optex.net/in/en/sec/
OPTEX KOREA CO.,LTD. (Korea)
URL: http://www.optexkorea.com/
OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
URL: http://www.optexchina.com/
-4-
360° CEILING MOUNT PASSIVE INFRARED DETECTOR
360° CEILING MOUNT PASSIVE INFRARED DETECTOR
SX-360Z, SX-360ZV
SX-360Z, SX-360ZV
FEATURES
Ceiling mount 360° PIR detector
Zoom area adjustment : ø18 m (ø60 ft.) at 2.4 –5.0 m (8 –16 ft.)
High density detection area with 276 zones
Selectable sensitivity (High, Medium or Low)
Selectable pulse count (TEST, 2 or 4)
Initial alarm memory (SX-360ZV)
LED remote control terminal
1
INSTALLATION HINTS
1
Avoid direct sunlight.
5
Do not install outdoors.
ø8.5
(ø0.33)
2
DETECTION AREA
TOP VIEW
9.0
mm (inch)
(30)
6.0
(20)
0
6.0
(20)
9.0
6.0
(30)
(20)
INSTALLATION INSTRUCTIONS
2
3
Avoid vapor or high
Avoid facing directly
to air conditioners or
humidity that can
heating vents.
cause condensation.
6
7
2.4 to 5.0 m
(8.0 to 16 ft.)
Install within 2.4 to 5.0 m (8.0 to 16 ft.)
Avoid moving objects in the
height from floor.
detection area.
SIDE VIEW
ZOOM "A" Position (See Section 7.)
9.0(30)
6.0(20)
3.0(10)
ZOOM "C" Position (See Section 7.)
9.0(30)
6.0(20)
3.0(10)
ZOOM "E" Position (See Section 7.)
0
6.0
9.0
(20)
(30)
9.0(30)
6.0(20)
3.0(10)
-1-
No.59-0527-8 150707
UL 59-0527-6 0908-31
EN
4
Do not obscure partially or
completely the detector's
field of view.
This symbol indicates
prohibition.
This symbol indicates
recommendation.
2.4(8.0)
3.0(10)
3.6(12)
4.2(14)
4.8(15)
0
3.0(10)
6.0(20)
9.0(30)
ZOOM
2.4(8.0)
3.0(10)
3.6(12)
0
3.0(10)
6.0(20)
9.0(30)
ZOOM
2.4(8.0)
0
3.0(10)
6.0(20)
9.0(30)
Unit: m (ft)

Advertisement

loading

Summary of Contents for Optex SX-360Z

  • Page 1 The LED can be enabled or disabled by using the LED ON/OFF PROBLEM PROBABLE CAUSE REMEDY switch or by using D.L. terminal. 1 LED ON/OFF Switch (SX-360Z only) Incorrect power supply voltage. Correct supply voltage to 360° CEILING MOUNT PASSIVE INFRARED DETECTOR 360° CEILING MOUNT PASSIVE INFRARED DETECTOR (disconnection, or low voltage) 9.5 - 18 VDC.
  • Page 2 I.A. A.M. I.A. A.M. I.A. A.M. Control memory UL requires SX-360Z to be connected to a UL listed power supply capable of providing a nominal input of 12 VDC and battery standby time of 4 hours. Panel Disarmed Note>> Blinking •...

This manual is also suitable for:

Sx-360zv