Dimensions; Specifications; Dimensions 7-1 Dimensions - Optex Smart Line Series Installation Instructions Manual

Hide thumbs Also See for Smart Line Series:
Table of Contents

Advertisement

7

DIMENSIONS

7-1 DIMENSIONS
8

SPECIFICATIONS

8-1 SPECIFICATIONS
< SL-200QDM, SL-350QDM, SL-650QDM, SL-200QDP, SL-350QDP, SL-650QDP >
Model
Maximum detection range
Maximum arrival distance*
1
*
Detection method
Selectable beam frequency
Interruption time
3
Power source*
10.5-30VDC
Normal
SBU-4*
1
Current
10.5-30VDC
draw
Optical
alignment
SBU-4*
1
10.5-30VDC
Peak
(UL evaluated)
Alarm output
Alarm period
Output*
4
*1
D.Q. output
Low battery output
Tamper output
Operating temperature
Operating humidity
Alignment angle
Dimension
Weight
International protection
< HU-3 (Option) >
1
*
Model
Power input
Current draw
Thermo switch
Operating temperature
Weight
Packages
ADVANCED
SL-200QDM
SL-350QDM
60 m / 200ft
100 m / 350 ft
600 m / 2,000ft
1,000 m / 3,500 ft 2,000 m / 6,500 ft
2
Normal: 10.5 - 30 VDC
Solar Battery Unit SBU-4*
26 mA
(T: 11 mA, R: 15 mA)
26 mA
(T: 9 mA, R: 17 mA)
36 mA
(T: 16 mA, R: 20 mA)
45 mA
(T: 17 mA, R: 28 mA)
40 mA
(T: 16 mA, R: 24 mA)
Form C relay: 30 VDC, 0.2 A
(D.Q. and Low battery can be switched.)
N.C. (contact output): 30 VDC, 0.1 A Opens when the cover removed.
2500 g (Total weight of the transmitter + receiver, excluding accessories)
HU-3
24 VAC/DC
210 mA max. per 1 piece / 420 mA max. per 1 unit
60°C (140°F)
-35°C - +60°C (-31°F - +140°F)
20 g (0.7oz) (Heater (x2))
Heater (x2), Connector (x4), Waterproof agent
96 (3.8)
SL-650QDM
200 m / 650 ft
600 m / 2,000ft
Quad infrared beam interruption detection
4 channels
Variable between 50/100/250/500 ms (4 steps)
1
(OPTION): 3.6 VDC
30 mA
(T: 15 mA, R: 15 mA)
35 mA
(T: 18 mA, R: 17 mA)
43 mA
(T: 20 mA, R: 23 mA)
60 mA
(T: 26 mA, R: 34 mA)
43 mA
(T: 20 mA, R: 23 mA)
Form C relay: 30 VDC, 0.2 A
2 sec (±1) (Nominal)
-35°C - +60°C (-30°F - 140°F)
95 % (max.)
±90° Horizontal, ±10° Vertical
2400 g (Total weight of the transmitter + receiver, excluding accessories)
*1
IP65
NOTE
These units are designed to detect an intruder and activate
an alarm control panel. Being only a part of a complete
system, we cannot accept responsibility for any damages or
other consequences resulting from an intrusion. These
products conform to the EMC Directive 2004/108/EC.
*1 not evaluated by UL
*2 "Maximum Arrival Distance" shows the optical margin for the
detection range.
*3 UL listed power-limited burglar alarm power supply.
*4 All relays are Dry-Contact and all outputs are power-limited.
*5 All interconnecting devices must be UL/c-UL listed.
*6 All inputs and outputs must be connected to power limited circuit only.
-19-
Unit: mm (inch)
STANDARD
SL-200QDP
SL-350QDP
60 m / 200ft
100 m / 350 ft
1,000 m / 3,500 ft 2,000 m / 6,500 ft
10.5 - 30 VDC
17 mA
(T: 6 mA, R: 11 mA)
21 mA
(T: 7 mA, R: 14 mA)
24 mA
(T: 7 mA, R: 17 mA)
Form C relay: 30 VDC, 0.2 A
SL-650QDP
200 m / 650 ft
22 mA
(T: 11 mA, R: 11 mA)
24 mA
(T: 10 mA, R: 14 mA)
33 mA
(T: 10 mA, R: 23 mA)