ALARM MEMORY FUNCTION
When an alarm is activated during alert status, the detector memorizes the alarm activation.
This will allow you to check which detector activated an alarm even when multiple units are installed.
In Remote mode, connect control voltage signal terminal (system arming status voltage output terminal) of control panel to ALARM
MEMORY INPUT terminal (11).
< Wiring example >
CONTROL PANEL
(1)
POWER
(2)
Control
voltage
(11)
signal
terminal
Receiver
< Indicator LED >
Alarm memory
indicator LED
< Dip switch >
Receiver
ON
ON
1 2 3 4 5 6 7
OFF
6
SOUND ASSIST FUNCTION
This function informs you of the operation and condition by sounds.
It works well on the two situations below:
< Optical alignment >
The optical alignment level can be checked with sound. The stronger the sensitivity, the faster the sound pattern. It sounds when
the alignment level indicators are illuminated, the tamper button is not pressed.
< Walk test >
Operation check can be performed by the beep sound at interruption for 5 minutes after the tamper button on both the transmitter
and receiver are pressed (after the cover is closed). The sound assist function automatically finishes after 5 minutes.
Sound assist
[ON/OFF]
POSITION
MODE
< Operating time chart >
Alarm
output
AUTO
Alarm
ON
(Timer mode)
memory
indicator
The alarm memory indicator is illuminated after approximately 5 minutes since the
last alarm generated, and kept illuminated for approximately 55 minutes.
The duration of illumination will not be extended even if an alarm generated while
the alarm memory indicator is illuminated. Approximately 55 minutes later, the
indicator will be automatically reset and returned to normal mode.
< Operating time chart >
Alarm
output
Security
system
Alarm
memory
indicator
When an alarm generated, the detector retains it in the memory.
When switching the security system from "System armed" to "System disarmed"
(switching the position), the alarm memory indicator of the detector that
memorizes the alarm memory indicator will be illuminated.
MANUAL
When putting the security system back on (switching the position), the alarm
OFF
(Remote mode)
memory indicator will be turned off and reset.
Once the reset is made, the alarm memory indicator will not be illuminated even if
the security system is switched to "System disarmed" until an alarm outputs again.
< Dip switch 6: Alarm memory [Positive/Negative] >
SOUNDING
DETECTOR
ON
POSITION
OFF
FUNCTION
Alarm
ON
OFF
5 min.
55 min.
Alarm
Armed
Disarmed
ON
OFF
Receiver
ON
1 2 3 4 5 6 7
Selectable
Receiver
Output
ON
1 2 3 4 5 6 7
Optical alignment
SL-QDM: Receiver and transmitter
SL-QDP: Receiver
ON
OFF
-14-
SL-QDM
SL-QDP
Alarm
Alarm
within
5 min.
5 min.
55 min.
Alarm
Alarm
Positive (N.C.)
System armed: OPEN or + 5~30VDC
System disarmed: 0~1VDC (grounded)
Negative (N.O.)
System armed: 0~1VDC (grounded)
System disarmed: OPEN or + 5~30VDC
SL-QDM
SL-QDP
Walk test
Receiver
ON
OFF