9.4.2

Environmental conditions

Climatic ambient conditions
Maximum permitted ambient temperature during operation
Temperature, tested according to IEC 60068-2-1, IEC 60068-2-2
Multi-touch devices
Intel Celeron processor
Intel i3 or i5 or Xeon processor
See "Permissible mounting positions" in the section "Installing and connecting the device", "Pre-
1
paring installation", "PRO device".
Relative humidity, tested in accordance with IEC 60068-2-78, IEC 60068-2-30
Operation
Storage/transport
Air pressure, in accordance with IEC 60068-2-13
Operation
Storage/transport
Mechanical ambient conditions
Vibration, tested according to DIN IEC 60068-2-6
Operation with CFast and
SSD
Storage/transport
Shock resistance, tested in accordance with IEC 60068-2-27, IEC 60068-2-29
Operation
Storage/transport
SIMATIC IPC477E PRO
Operating Instructions, 08/2017, A5E39912462-AA
Temperature during storage/transport
Storage/transport, gradient
all mounting positions
1
all mounting positions
1
5 ... 85% at 30 °C, no condensation
5 to 95 % at 25/55 °C, no condensation
1080 hPa to 795 hPa, corresponds to an elevation of 1000 m to 2000 m
1080 hPa to 660 hPa, corresponds to an elevation of 1000 m to 3500 m
5 Hz to 8.4 Hz: 3.5 mm
8.4 to 200 Hz: 9.8 m/s
5 to 8.4 Hz: 3.5 mm
8.4 to 200 Hz: 9.8 m/s
50 m/s
, 30 ms
2
250 m/s
, 6 ms
2
Technical specifications
9.4 Technical specifications
-20 °C to +60 °C
Max. 20 °C/h, no condensation
With SSD:
CFast only:
With SSD:
CFast only:
2
2
+0 to +45 °C
+0 to +45 °C
+0 to +40 °C
+0 to +45 °C
125