Technical specifications
9.4 Technical specifications
22" display
Display type
Active display area
Resolution
Possible colors
Brightness control
Backlighting
Half Brightness Life Time (MTBF
Pixel error class in accordance with ISO 9241-307
Touch force capacitive multi-touch screen
MTBF: Operating hours after which the maximum brightness is reduced by half compared to the
1
original value. MTBF is increased by using the integrated dimming function, for example time-
controlled via screen saver or centrally via PROFIenergy.
Interfaces
COM 1 / COM 2
2 x DisplayPort (DPP)
Keyboard
Mouse
USB
Ethernet
For unique labeling, the Ethernet ports are numbered on the enclosure. The numbering by the
1
operating system can differ.
Teaming can be set and initiated in the configuration interface. In teaming operation, jumbo
2
frames, e.g. for the camera application, are not supported.
124
)
1
1
With test pen, 2 mm diameter: 5 N
RS 232, max. 115 Kbps, 9-pin, D-sub plug
Connection of display devices with DisplayPort connection
Connection via USB port
Connection via USB port
Back of device:
4 × USB 3.0
Max. 2 high-current ports can be operated simultaneously
Max. 5 W for all USB devices
3 × RJ45 connection, Intel 1 x I219LM, 2 x I210
10/100/1000 Mbps, electrically isolated, teaming-capable
Operating Instructions, 08/2017, A5E39912462-AA
22"
LCD TFT
475 x 267 mm
1920 x 1080 pixels
Up to 16.7 million
Yes, value range 0 to 99
0 = backlighting off
LED
30000 h
II
SIMATIC IPC477E PRO
2