Mounting and connecting the HMI device
4.4 Connecting the device
4.4.2.3

Connecting the 24 VDC power supply

Electric shock and risk of fire
Voltages that exceed an extra-low voltage can cause electric shock or fire. Death or serious
bodily injury can result.
• The device may only be connected to a 24 V DC power supply that meets the
• The supplying source must be fused for a power rating < 240 VA; recommended fuse
Note
The 24 V DC power supply must be adapted to the input data of the device (see technical
specifications).
Requirements
● The device is installed.
● The protective conductor is connected.
● The connection terminal is wired.
● The corresponding 24 V DC power supply is switched off.
● A two-core cable with a cable cross-section of ≥ 0.5 mm
● A slotted screwdriver with approx. 3 mm blade.
48
WARNING
requirements of a safe extra-low voltage (SELV) according to IEC/EN/DIN
EN/UL 60950-1.
rating ≤ 8 A.
for the 24 V DC connection.
2
SIMATIC IPC477E PRO
Operating Instructions, 08/2017, A5E39912462-AA

Hide quick links: