Description Of The Product; Technical Specifications; Controls; Power Supply Cable - Hettich LegaDrive Operating And Installation Instructions

Hide thumbs Also See for LegaDrive:
Table of Contents

Advertisement

4. Description of the product

4.1 Technical specifications

Designation:
Lifting column system for an electri-
cally height adjustable workstation
Type:
LegaDrive
Place of installation:
Indoors (commercial)
Power supply:
230 V; 50 Hz / 120 V; 60 Hz
(depending on the control unit used)
Minimum height:
approx. 575 mm
Maximum height:
approx. 1250 mm
max. Loading capacity
per column:
80 kg, dynamic
Desk use:
- for 2 columns, dynamic load of
120 kg,
- for 3 columns, dynamic load of
120 kg
- for each additional column +40 kg
(Example: Desk with 5 columns
120 kg + 40 kg + 40 kg = 200 kg)
(in each at the centre above the desk
columns)
Number of lifting columns for
Compact-e-2 control unit: 2 columns
Compact-e-3 control unit: 1, 2 or 3 columns
Max. speed:
40 mm/s
Usage cycle:
10 %
(2 min. of continuous operation /
18 min. out of operation)
Ambient temperature
during operation:
5 °C to 40 °C
Storage /
transportation temperature: -40 °C to 70 °C
Air humidity
during operation
(non condensing):
5 % to 85 %
Max. noise level:
60 dB (A)
Protection class:
IP 20
Unauthorised changes and modifications to the lifting column
system are not permitted for safety reasons and rule out any
liability on the part of the manufacturer for any resultant
damage.

4.2 Controls

The lifting column system's controls are described below.

4.2.1 Power supply cable

Depending on place of use, the power supply cables are available
in different versions.
Note
i
Please pay attention to the information under
"Package contents".
Danger
Danger from electric shock!
Working on live components in the improper
manner presents a danger to life!
Work on electrical equipment must only be car-
ried out by authorised electricians!

Fig. 4: Various power supply cables

15