Figure 8-3: Assignment Of The Main Power Connections At The Motor Starter - Siemens SIMATIC ET 200pro Quick Manual

Motor starters
Hide thumbs Also See for SIMATIC ET 200pro:
Table of Contents

Advertisement

8.2.6
Connecting technology
Assignment of the main power connections
4
12
2
X1
Number
1
2
3
4
5
6
7
8
11
12
e
1)
only for sDSSte / sDSte and sRSSte / sRStee

Figure 8-3: Assignment of the main power connections at the motor starter

8-6
3
6
7
8
4
5
11
1
2
3
1
X2
Connection X1
HAN Q4/2 (pin)
Phase L1
Phase L2
Phase L3
Not used
Not used
Not used
PE
3
4
11
12
1
2
X3
Connection X2
HAN Q8/0 (socket)
L1 out
Not used
L3 out
Brake L1
(switched)
1)
Temperature sensor
Brake L3
(direct)
L2 out
1)
Temperature sensor
PE
SIMATIC - ET 200pro motor starter
GWA 4NEB 950 5661-02 DS 04
Connection X3
HAN Q4/2 (socket)
Phase L1
Phase L2
Phase L3
Not used
Not used
Not used
PE

Advertisement