Data formats and data records
SZL
Corresponding data record number
Length of the data record
Index
SZL
Corresponding data record number
Length of the data record
Index
8 bytes block information for additional data record objects
Table D-20: Data record 248 – identification data (Continued)
2. The part of the identification data assigned to each index can be found under
the corresponding data record number.
– All data records with identification data have a length of 64 bytes.
– The data records are structured according to the principle shown in the following
table.
Header information
SZL
Index
Length of the identification data
Number of blocks with identification data
Identification data
Index
Identification data for each index
Table D-21: Principle of structure of data records with identification data
The identification data is assigned to the indexes according to the following
table.
D-38
Content
Content
Length
Coding
(bytes)
(hex)
2
F1 11
2
00 E9
2
00 40
2
00 03
2
F1 11
2
00 EA
2
00 40
2
00 04
In total
48
Length
Coding
(bytes)
(hex)
2
F1 11
2
00 0x
2
00 38
2
00 01
2
00 0x
54
SIMATIC - ET 200pro motor starter