Figure 8-6: Circuit Diagram - Rse Reversing Starter, Standard And High Feature - Siemens SIMATIC ET 200pro Quick Manual

Motor starters
Hide thumbs Also See for SIMATIC ET 200pro:
Table of Contents

Advertisement

Circuit diagram for rev. starters RSe (ST and HF) and el. rev. starters sRSSte / sRSte
1
L1
2
I2
3
I3
PE
X1
4
Figure 8-6: Circuit diagram – RSe reversing starter, standard and high feature
There is an exact description for:
• Motor current I
• Inputs / actions in
• Emergency start in
Caution
Phase L1 is not fed via the semiconductors in electronic starters.
Before working on the output, switch off the starter protection switch first.
SIMATIC – ET 200pro motor starter
GWA 4NEB 950 5661-02 DS 04
7
Logic
Q1
Q1
Q2
1)
6
1 7 3 X2
in
'Present motor current', page 10-3
pres
Chapter 10.7
Chapter 10.12
DI 0.0
Ready via host / PLC
Motor on / current flow
DI 0.1
Group error
DI 0.2
General warning
DI 0.3
2)
Input 1
DI 0.4
2)
Input 2
DI 0.5
2)
Input 3
DI 0.6
2)
Input 4
DI 0.7
DI 1.0 - 1.5 Motor current I
Op. mode 'Manual operation local'
DI 1.6
DO 0.0
Motor CLOCKWISE
DO 0.1
Motor COUNTER-CLOCKWISE
DO 0.2
Brake
DO 0.3
Trip reset
DO 0.4
Emergency start
DO 0.5
Self-test
DO 1.7
Disable quickstop
Q2
Auxiliary switch
1) Brake control only with order number ending ... AA3
2) not present on standard
1
L1
2
I2
3
I3
PE
X3
pres
2)
8-9

Advertisement

Table of Contents
loading

Table of Contents