4.5 Parameter Display Set (Hide or Display)

4.5.1

Overview

You can choose to hide or display some parameters by selecting the set mode of each.
See Figure 4-18 Display Status for an interpretation of the Status of the Sets.
Refer to Table 4-4 for Functions of the Sets.
SET 1
SET 1
0 1 0 1
0 1 0 1
Example: Set 1 - 0 1 0 1 = OUTL (Displayed), AT (Hidden), AL1 (Displayed), AL2 (Hidden)
Example: Set 1 - 0 1 0 1 = OUTL (Displayed), AT (Hidden), AL1 (Displayed), AL2 (Hidden)
4.5.2

Functions of SETs

Set
Number
1.1
OUTL
1.2
AT
1.3
AL1
1.4
AL2
2.1
AL3
2.2
ANL1, ANH1, DP
2.3
LSPL, USPL
2.4
ANL2, ANH2
3.1
ALD1
3.2
ALT1
3.3
ALD2
3.4
ALY2
4.1
ALD3
4.2
ALT3
4.3
HYSA
4.4
CLO1, CHO1
8/05

Figure 4-18 Display Status

Table 4-4 Functions of Sets

Function
Number
DC1010/1020/1030/1040 Product Manual
SET N0.
SET N0.
Press SET key to change SET 0 ~ 9
Press SET key to change SET 0 ~ 9
0=Hide
0=Hide
1=Display
1=Display
Status of SET # . 1
Status of SET # . 1
Status of SET # . 2
Status of SET # . 2
Status of SET # . 3
Status of SET # . 3
Status of SET # . 4
Status of SET # . 4
# = Set Number
# = Set Number
Set
Function
5.1
CLO2, CHO2
5.2
CLO3, CHO3
5.3
RUCY,WAIT, SETA
5.4
IDNO, BAUD
6.1
SVOS (SP Comp = 0 or 1)
6.2
PVOS (PV Comp = 0 or 1)
6.3
UNIT
6.4
SOFT
7.1
CASC
7.2
OUD
7.3
OPAD
7.4
HZ
Configuration