[DIN SYNC] setting
You can change the settings of the following terminals.
The default setting is shown with *.
 OUT1 Sync Mode
Setting value: Sync24*, Sync48
Set the timing clock rate from the [DIN SYNC OUT1] terminal.
Check the specification of the connected equipment and select an
appropriate value.
• Sync24:
Timing clock rate of 24ppqn (Pulse Per Quarter Note)
The length of one quarter note is represented by 24 pulses.
• Sync48:
Timing clock rate of 48ppqn (Pulse Per Quarter Note)
The length of one quarter note is represented by 48 pulses.
Note
If you change the DIN SYNC setting during sequence playback, the
sequence playback will stop.