Changing the settings
 CV2 Range
Setting value: Hz/V 8V, V/Oct 1V, V/Oct 2V, V/Oct 5V*, V/Oct 10V,
V/Oct −5V
Set the [CV OUT2] terminal CV output method and output voltage
range.
Check the CV input specification of the connected equipment and
select an appropriate value. For details on the setting value, refer to
"CV1 Range" (page 119).
 CV2 Ref. Note
The setting values are as follows.
• When [Middle C] of the [Etc] setting is set to [C3]: C-2 to C1* to C6
• When [Middle C] of the [Etc] setting is set to [C4]: C-1 to C2* to C7
• When [Middle C] of the [Etc] setting is set to [C5]: C0 to C3* to C8
Set the note for setting output voltage of the [CV OUT2] terminal to 0
V. This setting is available when the [CV2 Range] setting is in the
V/Oct method.
For details, refer to "Notes" of "CV1 Ref. Note" (page 120).