4 Electrical Installation
• The cables must be in good condition, not have any sharp bends, and not be
pinched.
• The sheathing must not be damaged and must not have indentations or be
embossed at the cable entry.
• The minimum bending radius must not be below the accepted value.
• The cables must have the appropriate temperature rating.

4.3 Connect the wiring harness to the control panel

1. Connect the female circular connector of the wiring harness to the FST
module.
2. Connect the spliced terminals of the wiring harness to the control panel.
Orange
Black
Brown
Green
Yellow
Red
White
Blue
14
Wire color
PrimeGuard 2
terminal
Key switch Batt
15
12
19
20
14
4
3
FST Installation, Operation, and Maintenance Manual
Control panel
PV102P terminal
Key switch Batt
V+
6, 7, and 8
BATT-
14
DIG IN 1
10
CAN LO
11
CAN HI
18
BATT +
12
RS 485 L
13
RS 485 H
Description